Introduction
This chapter describes how to set Transmit Time Interval.
Downlink Payload
TDC can be controlled by Downlink Payload.
For example:
AT+TDC=0x258=600s
Payload: 01 00 02 58 TDC=600s
The time interval is represented by hexadecimal conversion to decimal.
If the payload=0100003C, it means set the END Node’s TDC to 0x00003C=60(S), 3C (HEX) = 60 (decimal),while type
code is 01.
Payload: 01 00 00 1E TDC=30s Payload: 01 00 00 3C TDC=60s
Downlink Method
See use note for different serves Servers Note